Chemical methods are used to isolate and purify very small amounts of the element of interest (e.g.

carbon, beryllium, aluminium, iodine, uranium or plutonium), and for preparing the appropriate target material for measurement in the accelerators.

The traditional accelerator was first developed in the early 1930s for nuclear physics research.

In 1939, UC Berkeley scientists Luis Alvarez and Robert Cornog were the first to use AMS in the detection of Now, over 70 years later, cyclotrons have been replaced by an accelerator type with greater energy stability: the tandem electrostatic accelerator.

This process, called sputtering, separates neutral, as well as positive and negative ions from the sample surface.

The sample is held at a negative potential, and negatively charged ions are accelerated away from the sample, resulting in a beam of negative ions (Figure 2, below). The low energy (~5-10 ke V) diverging beam that leaves the ion source is accelerated, focused and transported to the accelerator by the injector system. Most AMS systems use sequential injection, a process that switches between stable and rare isotopes via the application of varying voltages to the electrically insulated vacuum chamber of the analyzer magnet.

At CAMS LLNL, a magnetic quadrupole lens focuses the desired isotope and charge state to a high-energy mass spectrometer which passes The magnetic quadrupole and electrostatic selectors coupled together ensure high selectivity and sensitivity, respectively.

A recombinator is used following sequential injection, which is a sequence of magnetic analyzers and quadrupole lenses that focus the stable and rare isotopes so they recombine and enter the accelerator together.

An electrostatic accelerator works by accellerating particles though a magnetic field generated by high voltages using a mechanic transport system that continuously transports charges from ground to the insulated high-voltage terminal.

All tandem accelerators with a maximum terminal voltage above 5 MV use such a mechanical system.

It is preferrable to remove at least three electrons because by this process that molecular isobars of The negative ions are changed to positively charged ions and are thus accelerated back to the ground potential in the high-energy part of the accelerator.

Transmission through a foil changes with time due to radiation damage and foil thickening, thus gas strippers are used in all modern analyzers due to their increased transmission stability.